Introduction
Before the Rad-5/5v Handheld Pulse Oximeter can be used in a clinical setting, it needs to
be inspected, properly setup and the batteries need to be installed.
Unpacking and inspection
Remove the instrument from the shipping carton and examine for signs of shipping dam-
age. Check all materials against the packing list. Save all packing materials, invoice and
bill of lading. These may be required to process a claim with the carrier.
If anything is missing or damaged, contact the Technical Service Department. The contact
address and phone numbers are listed in Section 9,
Service and Repair
.
Preparation for monitoring
The following sections of the manual describe the preparation, set-up and initial installation
of the Rad-5/5v Handheld Pulse Oximeter.
POWER REQUIREMENTS
The Rad-5 and Rad-5v are powered by 4 “AA” alkaline batteries. Do not use any other type
of batteries or power source to run the device. The battery compartment is accessed from
the back of the device. To install the batteries first remove the battery cover by depressing
the small rectangular button at the bottom of the cover, and sliding the cover down off the
bottom of the device. Install the batteries in the directions indicated by the battery icons
inside the battery compartment. Replace the battery cover by sliding it back up from the
bottom of the device until the rectangular locking button snaps back into position.
Battery charge level is indicated by four LED indicators at the bottom of the front panel. All
four indicators will be lit when the batteries are full, with fewer indicators being lit as the bat-
teries lose their charge. When less than ten (10) percent battery life remains, the final bat-
tery indicator will begin to flash and an audible alarm will sound.
WARNING: USE ONLY ALKALINE BATTERIES. USE OF NON ALKALINE BAT-
TERIES MAY AFFECT THE ACCURACY OF THE BATTERY LEVEL METER.
WARNING: USE OF BATTERIES WITH A CELL VOLTAGE OF MORE THAN 1.5V
COULD CAUSE DAMAGE TO THE DEVICE.
WARNING: REMOVE BATTERIES IF UNIT IS NOT TO BE USED FOR SOME
TIME.
system description
2-4 Rad-5/5v Signal Extraction Pulse Oximeter Operator’s Manual Rad-5/5v Signal Extraction Pulse Oximeter Operator’s Manual 3-1
2
3
setup
CONTROL / INDICATOR DESCRIPTION
1
Serial Number Label Located inside battery compartment and on back of device
2
Agency Approvals Label
3
Battery Cover
4
Battery Cover Release
Press down and slide the battery cover off the bottom of the
oximeter
Rad-5/5v rear panel
SYMBOL DESCRIPTION
Caution, consult accompanying documents
BF applied part complying with IEC 60601-1.
WEEE Compliant
Symbols
2
3
1
X X X X X X
FOR PLACEMENT ONLY
2XXX
4
X X X X X X
FOR PLACEMENT ONLY
2XXX
AA
AA
AA
AA
1
X X X X X X
FOR PLACEMENT ONLY
2XXX
1
Masimo Corporation
Irvine, CA 92618
USA
Rad-5
80 FK
UL 60601-1
R
x
Only
Masimo Corporation
Irvine, CA 92618
USA
Rad-5v
80 FK
UL 60601-1
R
x
Only
Not for Continuous Monitoring