Masimo Radical Signal Extraction Manual do Operador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 5
1-2 Rad-57 Signal Extraction CO-Pulse Oximeter Operator’s Manual
1
Rad-57 Signal Extraction CO-Pulse Oximeter Operator’s Manual 1-3
1
Warnings, cautions and notes
Please read and follow any warnings, cautions and notes presented throughout this
manual. An explanation of these labels are as follows:
A WARNING is provided when actions may result in a serious outcome (i.e., injury,
serious adverse affect, death) to the patient or user. Look for text in a gray shaded box.
Sample of Warning:
WARNING: THIS IS A SAMPLE OF A WARNING STATEMENT.
A CAUTION is given when any special care is to be exercised by the patient or user to
avoid injury to the patient, damage to this device or damage to other property.
Sample of Caution:
CAUTION: THIS IS A SAMPLE OF A CAUTION STATEMENT.
A NOTE is provided when extra general information is applicable.
Sample of Note:
NOTE: This is a sample of a Note.
overview
1
overview
Product Description
The Rad-57 Rainbow SET Pulse CO-Oximeter is a noninvasive, arterial oxygen saturation
and pulse rate monitor. The Rad-57 features a multicolored LED display that continuously
displays numeric values for SpO
2
and pulse rate, a Low Signal IQ Indicator (Low SIQ)
indicator, LED indicator bars for Perfusion Index (PI), Carboxyhemoglobin saturation
(%SpCO), alarm status, alarm silence, battery life and SpCO sensor connected.
The following list outlines the key features and benefits of the Rad-57 Pulse CO-Oximeter.
FEATURES AND BENEFITS
Clinically proven Masimo SET
TM
technology performance
Proven for accurate monitoring in motion and low perfusion environments
SpO
2
, pulse rate, alarm, Perfusion Index and % SpCO displays
Low Signal IQ (SIQ) indicator
Lightweight, convenient handheld design
Up to 8 hours of continuous use on 4 “AA” alkaline batteries
Visual battery life indicator
Audible Alarm for sensor-off and low battery
Alarms for high/low SpO
2
, high/low pulse rate and SpCO
FastSat
TM
(for SpO
2
measurement)
Three sensitivity levels - Max, Normal and APOD
TM
(for SpO
2
measurement)
72 hours of trending memory
Adjustable alarm volume
Adjustable averaging 2 to 16 seconds
INDICATIONS FOR USE
The Rad-57 Pulse CO-Oximeter and accessories are indicated for the continuous,
noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO
2
), pulse
rate and carboxyhemoglobin saturation (measured by an SpCO sensor). The Rad-57
and accessories are indicated for use with adult, pediatric and neonatal patients during
both motion and no motion conditions, and for patients who are well or poorly perfused in
hospitals, hospital-type facilities, mobile and home environments.
Vista de página 5
1 2 3 4 5 6 7 8 9 10 11 ... 29 30

Comentários a estes Manuais

Sem comentários